2-Output Transformer type clock distributor

Prezzo di listino $98.00

Spese di spedizione calcolate al momento del pagamento.
<<<Notice and apology regarding the sales period >>>
We have closed orders for 2024. (All items are marked as "SOLD OUT.")
We will not be accepting orders in January 2025 due to the annual maintenance of our calibration equipment.
So, we will start accepting orders again on February 1, 2025.
We appreciate your patience and understanding.

About 2-Output Transformer type clock distributor :


MODEL: CYB-DS01

Divides the 10MHz clock of the cyber shaft clock product into two.
Since it is a transformer type, it can be distributed with almost no deterioration in clock quality.
The input impedance is 50 ohms.
The output impedance is 50 ohms x 2 systems.
All products can be used with peace of mind by measuring the SWR for each unit and confirming the characteristics.

Specifications :
■ Input SWR 1.1 or less (10 MHz when 50Ω impedance is connected)
■ Output SWR 1.2 or less (10 MHz when 50Ω impedance is connected)
■ Compatible impedance: Clock input side 50Ω, output side 50Ω, 2 systems

* The input side must be connected to the 50Ω impedance output.
* The output level of this distributor will decrease.
For output level 1.6V-pp → Approximately 1.1V-pp
Please note that the output level of this item will be low, so the connected audio device may not be locked.
* To connect the output side to an audio device with a 75Ω input impedance, use our 50Ω matching adapter to match the input impedance to 50Ω.
* There is no isolation between GND.
Therefore, please note that the two devices connected to the output may induce ground loop noise.
* Use 50Ω BNC cable for all cables to be connected.
* When using, it is necessary to connect a 50Ω device to both of the 2 outputs. It cannot be used with one side open.
* Only for our 10MHz clock products. We cannot guarantee the characteristics when the conditions are different, such as other frequencies.